M M M M M M
 
SM SM SM SM SM SM SM SM
 

 

Products from Ross Valve

http://www.rossvalve.com/

If you cannot download the brochures linked below,
or if you would like further information,
you can receive product literature via postal mail.

Please phone Craig Moore at 716-667-0714 or Nick Kochan at 315-453-4046 .

Relief Valve 50RWR

Sizes: 4-48
Type: Throttling
Primarily controlled by hydraulic pressure
Located in tee connection
Purpose: To prevent excessive pressure in the main line Inlet Pressure: Maximum: 300 psi
Inlet Pressure: Minimum: 5 psi
Construction: Body: 4"-36"—Cast iron (semi-steel) with bronze trim
40"-48"—Ductile iron, with bronze/stainless steel trim. (Can also be added to other basic valves as a customized feature.)
Click for detailed product information, or email Craig Moore, phone 716-667-0714.

Back Pressure Sustaining Relief Valve, 50RWR

Sizes: 4-48
Type: Throttling
Primarily controlled by hydraulic pressure
Located in tee connection
Purpose: To prevent excessive pressure in the main line
Inlet Pressure: Maximum: 300 psi
Inlet Pressure: Minimum: 5 psi
Construction: Body: 4"-36"—Cast iron (semi-steel) with bronze trim
40"-48"—Ductile iron, with bronze/stainless steel trim. (Can also be added to other basic valves as a customized feature.)
Click for detailed product information, or email Craig Moore, phone 716-667-0714.

Back Pressure Sustaining Relief Valve, 23RWR

Sizes: 1 1/2 - 3
Type: Direct Acting Throttling
Primarily Controlled By: Hydraulic pressure
Located: Back Pressure Sustaining: In line
Relief: In tee connection
Purpose: Back Pressure Sustaining: To prevent inlet pressure from falling below a preset minimum
Relief: To prevent excessive pressure in the main line
External Piping: None
Ends: Flanged or screwed
Inlet Pressure: Maximum: 300 psi
Inlet Pressure: Minimum: 5 psi
Class: 125 ANSI for inlet pressures to 180 psi, 250 ANSI for inlet pressures to 300 psi
Fluid: Cold water service
Construction: Cast iron body, bronze cover, pilot, piston and internal trim
Control Valves: None
Click for detailed product information, or email Craig Moore, phone 716-667-0714.

Back Pressure Sustaining Relief Valve, 20WR

Sizes: 1-3
Type: Pressure positioned
Primarily Controlled By: Hydraulic pressure (upstream)
Located: Back Pressure Sustaining: In line
Relief: In tee connection
Purpose: Back Pressure Sustaining: To control inlet pressure within close tolerance
Relief: To prevent excessive pressure in the main line within close tolerance
Body Design: Angle (90 degree)
External Piping: None
End: Flanged or Female NPT
Inlet Pressure: Maximum: 1000 psi
Inlet Pressure: Minimum: 30 psi
Construction: All bronze body
Control Valves: None
Click for detailed product information, or email Craig Moore, phone 716-667-0714.

Hydrant Relief Valve, 20-WR-H

Sizes: 2 1/2 hose connections
Type: Throttling
Primarily Controlled By: Hydraulic pressure
Located: Portable: Attached to a hydrant
Purpose: To protect a system that involves a hydrant from over pressure when storage is out of service
Inlet Pressure: Maximum: 350 psi
Inlet Pressure: Minimum: 5 psi
Construction: All Bronze
Control Valve: Internal Pilot: Built in
Option: Angle body design (90 degree)
Basic Application: Protect systems against excessive pressures, for example where storage is taken out of service periodically and the system is kept pressurized by a running pump and when doing maintenance on a tank.
Click for detailed product information, or email Craig Moore, phone 716-667-0714.

Pressure Reducing Valve, 40WR

Sizes: 4-48
Type: Throttling
Primarily Controlled By: Hydraulic pressure
Located: In line Purpose: To prevent outlet pressure from exceeding a preset maximum level
Inlet Pressure: Maximum: 300 psi
Inlet Pressure: Minimum: 5 psi
Construction: Body: 4"-36"—Cast iron (semi-steel) with bronze trim
40"-48"—Ductile iron, with bronze/stainless steel trim
Control Devices:
Strainer: Model 5F-2
Valves: Needle
Pilot: Pressure Reducing: Model 40WR
With internal sensing port or equipped to receive a separate sensing line. (Can also be added to other basic valves as a customized feature.)
Click for detailed product information, or email Craig Moore, phone 716-667-0714.

Pressure Reducing Valve, 23WR

Sizes: 1 1/2 - 3
Type: Throttling
Primarily Controlled By: Hydraulic pressure
Located: In line
Purpose: To prevent pressure from the main valve from exceeding a preset maximum level.
Ends: Female NPT or flanged
Inlet Pressure: Maximum: 300 psi
Inlet Pressure: Minimum: 20 psi
Class: 125 ANSI for inlet pressures to 180 psi
250 ANSI for inlet pressures to 300 psi
Discharge pressure: 5 psi-250 psi
Fluid: Cold water service
Construction: Cast iron body/bronze cover, pilot, piston and internal trim
Control Valves:
Orifice Pilot: Pressure Reducing: Model 23WR
Click for detailed product information, or email Craig Moore, phone 716-667-0714.

Pump Control Valve, 42WS

Sizes: 2-48
Type: Nonthrottling system
Primarily Controlled By: Electricity
Located: In line
Purpose: To control surges caused by pump starting and stopping
Inlet Pressure: Maximum: 300 psi
Inlet Pressure: Minimum: 5 psi
Construction: Cast iron (semi-steel) body with bronze trim
Body: 2"-36"—Cast iron (semi-steel) with bronze trim
40"-48"—Ductile iron, with bronze/stainless steel trim
Control Devices:
Strainer: Model 5F-2
Valves:
Needle: (Closing Control)
Needle: (Opening Control)
Pilot: Solenoid: 3 Way
Other System Components:
Limit Switch: Wired to normally closed contact
Click for detailed product information, or email Craig Moore, phone 716-667-0714.

Single Acting Altitude Valve, 30AWR

Sizes: 4-48
Type: Nonthrottling
Primarily Controlled By:Hydraulic pressure
Located: In line leading to storage
Purpose: To prevent elevated storage from overflowing
Band: Fixed within 9-4
Inlet Pressure: Maximum: 300 psi
Inlet Pressure: Minimum: 5 psi
Construction: Body: 4"-36"—Cast iron (semi-steel) with bronze trim
40"-48"—Ductile iron, with bronze/stainless steel trim
Plugged Tee: Incorporated in piping for attachment of a separate sensing line—if provided
Control Devices:
Strainer: Model 5F-2
Pilot: Model 30AWR

Click for detailed product information, or email Craig Moore, phone 716-667-0714.

Double Acting Altitude Valve, 40DAWR

Sizes: 4-48
Type: Nonthrottling
Primarily Controlled By: Hydraulic pressure
Located: In line between distribution (supply/user) and storage
Purpose: To prevent exceeding a maximum preset storage pressure/Let water flow through the same line from storage to user
Band: Fixed within 9-4
Inlet Pressure: Maximum: 300 psi
Inlet Pressure: Minimum: 5 psi
Construction: Body: 4"-36"—Cast iron (semi-steel) with bronze trim
40"-48"—Ductile iron, with bronze/stainless steel trim
Control Devices:
Strainer: Model 5F-2
Pilot: Altitude: Model 40DAWR
Click for detailed product information, or email Craig Moore, phone 716-667-0714.

See products from manufacturers we represent

 

Photos of Ross Valve products in use
Ross, 66 inches Valve installation, N. Greenbush
66-inch multi-orifice valve unit Installing a vault in N Greenbush, NY
   
Ross 24-inch valve at 24” Pump Control Valves for Erie County Water Authority’s Van De Water Low Lift Pump Station24” Pump Control Valves for Erie County Water Authority’s Van De Water Low Lift Pump Station
24” pump control valves for Erie County Water Authority’s
Van De Water Low Lift Pump Station
   
Ross-Crispin installation

Ross Valve/Crispin Valve installation: Chestnut Ridge Booster Pump Station, Orchard Park, NY

   
Ross

Ross Valve product: 4" Anticavitation valve
followed by a single acting altitude valve, Canandaigua, NY